Some drivers (example: qualcomm-battmgr, present on Snapdragon X1 laptops) expose the current_now and power_now values in sysfs as negative int when the device is discharging, positive when charging. This breaks the battery runtime estimation in Waybar, as it expects a uint32 for power_now. Change the battery module to use the absolute values of current_now and power_now.